Framework try-in

Содержание

Слайд 2

by

FRAMEWORK TRY-IN
IN R.P.D

Ismail saleh
2020

by FRAMEWORK TRY-IN IN R.P.D Ismail saleh 2020

Слайд 3

The metal framework is tried in the patient's mouth before the jaw

The metal framework is tried in the patient's mouth before the jaw
relation record.
Unadjusted frameworks tend to place undesirable torquing forces on teeth.
I- Inspection of the framework on the cast:
II. Seating the metal framework intra-orally.

Слайд 4

- careful examination of the stone cast surface. The master cast should

- careful examination of the stone cast surface. The master cast should
be checked for any abrasion which indicates Areas of ' excessive contact between the framework and stone.

I- Inspection of the framework on the cast:

Слайд 5

• Proper polish of the outer and inner surfaces of the framework.

• Proper polish of the outer and inner surfaces of the framework.
The tissue surface of the casting is inspected for nodules, roughness, and imperfections.
- Nodules should be removed by tapered stones and smoothed with rubber discs.

The framework should be removed from the cast and evaluated for:

Слайд 6

• Proper design and accurate components,
• The framework is adjusted until it

• Proper design and accurate components, • The framework is adjusted until
smoothly comes on and off the master cast ( easy insertion and remove ) .
• Accurate fit of the framework on the cast and the rests need to be completely seated with intimate contact.
• The presence of tissue stops should also be ensured in combined acrylic- metal bases.
• Proper thickness of the components .

The metal framework is inspected on the cast to ensure:

Слайд 7

The polished framework should be placed in the mouth without extreme force

The polished framework should be placed in the mouth without extreme force
to prevent damage to the teeth, periodontal tissues .
First seat it by orienting the clasps on the abutment teeth, then press on the rest areas in the direction of the path of insertion.

II. Seating of the metal framework intra-orally:

Слайд 8

- The following should be noticed while trying-in the framework:
1- Clicking when

- The following should be noticed while trying-in the framework: 1- Clicking
seated .
2- Tilting while seating .
3- Verifying Reciprocation .
4- Verifying Fit .
5- Inability to seat the framework in the planned position .
6- Deformed Clasp.
7- Occlusal interference from denture framework.

Слайд 9

1- Clicking when seated:
usually results from:
• Rigid part of the frame is

1- Clicking when seated: usually results from: • Rigid part of the
forced into an undercut.
• End of reciprocal arm is below an undercut.
• Extra bulk of metal on the minor connector.
Correction:
The tissue surface is coated with a disclosing material and seated in the mouth ( P.I.P ), detected the cause and TTT.

Слайд 10

Materials that are used to detect interferences include:
Pressure indicating paste
Chloroform and rouge.
Kerr’s

Materials that are used to detect interferences include: Pressure indicating paste Chloroform
impression wax.
Mark and remove internal interferences until the framework is fully seated.

Слайд 11

2- Tilting while seating:
results from:
• Retentive arm is more rigid in one

2- Tilting while seating: results from: • Retentive arm is more rigid
side than the other side.
• One clasp is extended into a deeper undercut than the other side clasp.
Correction:
- The stronger or resisting clasp must be altered to have a more taper or more flexible clasp.
- The extended clasp into a deeper undercut must be shortened.

Слайд 12

3- Verifying Reciprocation:
results from:
Each reciprocal arm should contact its abutment just prior

3- Verifying Reciprocation: results from: Each reciprocal arm should contact its abutment
to, or at the same moment as its associated retentive arm.
it brace the tooth against the forces applied by the flexing retentive arm.
Unreciprocated forces lead to mobility in the abused abutment and periodontal breakdown.
Correction:
Detection of interference using disclosing material and grinding of this interference using grinding diamond stone.

Слайд 13

4- Verifying Fit:
Lack of passive placement may results from:
1. Inaccurate impression.
2. Presence

4- Verifying Fit: Lack of passive placement may results from: 1. Inaccurate
of surface defects (such as nodules) on the contacting surface.
3. The clasp arm is active all the time.

Correction:
1. Removal of the cause.
2. If the reason is faulty impression, repeat the impression and construct a new metallic framework.
3. Surface defects should be removed after been indicated using disclosing material and removed using diamond stones.

Слайд 14

5- Inability to seat the framework in the planned position:
Results from:

5- Inability to seat the framework in the planned position: Results from:
Inaccuracy or error in the impression procedures.
• Errors occurring in pouring the cast.
• Improper laboratory procedures during waxing and casting of the metal framework.
Correction:
In this case, another impression is made to obtain an accurate cast upon which a new framework is constructed.

Слайд 15

6- Deformed Clasp :
A clasp under tension may force the frame to

6- Deformed Clasp : A clasp under tension may force the frame
assume wrong or tilted position .
The cast clasp or wrought wire clasp may have been deformed during finishing and polishing .
This condition is mostly seen when a wrought clasp has been improperly contoured .
Correction:
Remake the deformed clasp or metal denture base .

Слайд 16

- Any occlusal interference from occlusal rests or other parts of the

- Any occlusal interference from occlusal rests or other parts of the
denture framework must be eliminated before recording jaw relation.
Much of these adjustments can be avoided by:
a- proper treatment plan.
b- proper mouth preparation.
c- proper partial denture design were followed.

7- Occlusal interference from denture framework:

Слайд 17

I- Inspection of the framework on the cast
Fig. 3 : Initial contacts

I- Inspection of the framework on the cast Fig. 3 : Initial
on the abutment teeth
Fig. 4 : Continuously follow the same path
guided by the proximal plates

Слайд 18

Fig. 5 a and b: The stability of the casting should be

Fig. 5 a and b: The stability of the casting should be
checked under finger pressure. b, occlusal rest and proximal plate should be seated properly in their positions

Fig. 6 and a b: Reciprocal arm should be above the survey line (a), while retentive
arm is below it (b).

Слайд 19

Fig. 7 a and b: Inspection of the RPD Framework Casting.
The Framework

Fig. 7 a and b: Inspection of the RPD Framework Casting. The
is adjusted until it smoothly comes on and off the master cast. The rests needs to be completely seated with intimate contact.

Слайд 21

Physiologic Adjustment of Framework

The framework is tried in the mouth after being

Physiologic Adjustment of Framework The framework is tried in the mouth after
checked on the cast and the laboratory sheet. Check the correct and proper seating of the framework. It is recommended that the trial insertion of the metal framework should initially be under taken without the addition of any wax rims.

Fig. 8 a and b: Paint a thin coating of gold rouge with a brush on The tooth-contacting areas of the framework. To determine the interference areas.

Слайд 22

Fig. 9 a and b: Adjustments are made to the framework in

Fig. 9 a and b: Adjustments are made to the framework in
the areas that are binding with carbide burs and high speed grinding stones.

Fig. 10 a and b: Verification of seating of the metal frame work.
Carefully fit & adjust the casting until excellent adaptation in the mouth is achieved.

Имя файла: Framework-try-in.pptx
Количество просмотров: 41
Количество скачиваний: 0