Write sensor parameter via Siemens TI

Слайд 2

Date: 23.12.2016

Page:

© ifm ecomatic gmbh

Contents:

Connect units
Configuration – AL1100 in TIA Portal

Date: 23.12.2016 Page: © ifm ecomatic gmbh Contents: Connect units Configuration –
V13
IO-Link parameter – O5D100
Read sensor parameter – S7-315-2 PN/DP
Read sensor parameter – S7-1500

Слайд 3

Date: 23.12.2016

Page:

© ifm ecomatic gmbh

Connect units

Laptop / PC
with Siemens TIA Portal

Date: 23.12.2016 Page: © ifm ecomatic gmbh Connect units Laptop / PC
V13

AL1100

Siemens PLC

Слайд 4

Date: 23.12.2016

Page:

© ifm ecomatic gmbh

Install GSDML files for this device –

Date: 23.12.2016 Page: © ifm ecomatic gmbh Install GSDML files for this
Get GSDML file

Download current GSDML file
Update your cataloge
Choose AL1100 and insert it to your network

2. Configuration – AL1100 in TIA Portal V13

Слайд 5

Date: 23.12.2016

Page:

© ifm ecomatic gmbh

Connect O5D100 to port 1

Download IODD PDF

2.

Date: 23.12.2016 Page: © ifm ecomatic gmbh Connect O5D100 to port 1
Configuration – AL1100 in TIA Portal V13

Слайд 6

Date: 23.12.2016

Page:

© ifm ecomatic gmbh

Connect O5D100 to port 1

This device has

Date: 23.12.2016 Page: © ifm ecomatic gmbh Connect O5D100 to port 1
2Byte cyclic data
Last 4bits has to ignore

2. Configuration – AL1100 in TIA Portal V13

Слайд 7

Date: 23.12.2016

Page:

© ifm ecomatic gmbh

Set-up your port length

Choose ‚IO-Link 2Byte +

Date: 23.12.2016 Page: © ifm ecomatic gmbh Set-up your port length Choose
PQI‘
Put it with Drag&Drop to your port
Set your input-area

2. Configuration – AL1100 in TIA Portal V13

Слайд 8

Date: 23.12.2016

Page:

© ifm ecomatic gmbh

Parameter 80 – Laser On/Off

3. IO-Link parameter

Date: 23.12.2016 Page: © ifm ecomatic gmbh Parameter 80 – Laser On/Off
– O5D100

8 Bit -> value ‚1‘ to LEN (IO_Link_Device function block)

Слайд 9

Date: 23.12.2016

Page:

© ifm ecomatic gmbh

Find the ID for IO_Link_Device function block

Date: 23.12.2016 Page: © ifm ecomatic gmbh Find the ID for IO_Link_Device

First input address of the port

4. Read sensor parameter – S7-315-2 DP/PN

Слайд 10

Date: 23.12.2016

Page:

© ifm ecomatic gmbh

Find the ID for IO_Link_Device function block

Date: 23.12.2016 Page: © ifm ecomatic gmbh Find the ID for IO_Link_Device

First input address of the port
ID and PORT is linked! If you change your port, you have to change your ID as well!!
CAP = 16#B400

4. Read sensor parameter – S7-315-2 DP/PN

Слайд 11

Date: 23.12.2016

Page:

© ifm ecomatic gmbh

Find the data

There will appear your data

4.

Date: 23.12.2016 Page: © ifm ecomatic gmbh Find the data There will
Read sensor parameter – S7-315-2 DP/PN

Слайд 12

Date: 23.12.2016

Page:

© ifm ecomatic gmbh

Find the ID for IO_Link_Device function block

Date: 23.12.2016 Page: © ifm ecomatic gmbh Find the ID for IO_Link_Device

Hardware indentifier has convert to hexadecimal
270 dec -> 10E hex

5. Read sensor parameter – S7-1500

Слайд 13

Date: 23.12.2016

Page:

© ifm ecomatic gmbh

Find the ID for IO_Link_Device function block

Date: 23.12.2016 Page: © ifm ecomatic gmbh Find the ID for IO_Link_Device

Hardware indentifier
ID and PORT is linked! If you change your port, you have to change your ID as well!!
CAP = 16#B400

5. Read sensor parameter – S7-1500