Слайд 2© 2001, Halliburton Energy Services, Inc.
March 7, 2001
Calculating and Using Sensor to
Bit Distance
Слайд 3© 2001, Halliburton Energy Services, Inc.
March 7, 2001
Sensor Measure Point
Used to calculate
sensor to bit distance
Surveys referenced to where measurements made, not to bit
Gamma referenced to where measurements made, not to bit
Слайд 4© 2001, Halliburton Energy Services, Inc.
March 7, 2001
Identify Sensor and Probe Type
Directional
Only
DEP, DEP2, PCD
Gamma
PCG
Слайд 5© 2001, Halliburton Energy Services, Inc.
March 7, 2001
Sensor Measure Point – DEP2
Слайд 6© 2001, Halliburton Energy Services, Inc.
March 7, 2001
Sensor Measure Point - PCD
Слайд 7© 2001, Halliburton Energy Services, Inc.
March 7, 2001
Sensor Measure Point - PCG
Слайд 8© 2001, Halliburton Energy Services, Inc.
March 7, 2001
Bottom Ring to
Probe Bottom Distance
Measure
the distance from the Bottom Ring Assembly to the bottom of the probe.
(6.3’)
Слайд 9© 2001, Halliburton Energy Services, Inc.
March 7, 2001
Obtain BHA Tally
Bit 8 ½” 0.75’
Motor 6 ¾” 24.35’
Stabilizer 6
¾” 5.72’
NMDC 6 ¾” 29.87’
HOS 6 ¾” 6.21’
X-over sub 6 ¾” 2.37’
NMCD 6 ¾” 28.53’
Слайд 10© 2001, Halliburton Energy Services, Inc.
March 7, 2001
Obtain Bore Depth from Spacer
Stack Calculations
54.25”
54.25”
Слайд 11© 2001, Halliburton Energy Services, Inc.
March 7, 2001
Calculations
Add lengths from bit to
top of MWD mounting sub or collar
66.9’
Subtract HOS Bore Depth
62.38’
Subtract distance from bottom ring to bottom of probe
56.08’
Add sensor measure point (PCD)
56.94’