(011)Sensor to bit calculations

Слайд 2

© 2001, Halliburton Energy Services, Inc.

March 7, 2001

Calculating and Using Sensor to

© 2001, Halliburton Energy Services, Inc. March 7, 2001 Calculating and Using Sensor to Bit Distance
Bit Distance

Слайд 3

© 2001, Halliburton Energy Services, Inc.

March 7, 2001

Sensor Measure Point

Used to calculate

© 2001, Halliburton Energy Services, Inc. March 7, 2001 Sensor Measure Point
sensor to bit distance
Surveys referenced to where measurements made, not to bit
Gamma referenced to where measurements made, not to bit

Слайд 4

© 2001, Halliburton Energy Services, Inc.

March 7, 2001

Identify Sensor and Probe Type

Directional

© 2001, Halliburton Energy Services, Inc. March 7, 2001 Identify Sensor and
Only
DEP, DEP2, PCD
Gamma
PCG

Слайд 5

© 2001, Halliburton Energy Services, Inc.

March 7, 2001

Sensor Measure Point – DEP2

© 2001, Halliburton Energy Services, Inc. March 7, 2001 Sensor Measure Point – DEP2

Слайд 6

© 2001, Halliburton Energy Services, Inc.

March 7, 2001

Sensor Measure Point - PCD

© 2001, Halliburton Energy Services, Inc. March 7, 2001 Sensor Measure Point - PCD

Слайд 7

© 2001, Halliburton Energy Services, Inc.

March 7, 2001

Sensor Measure Point - PCG

© 2001, Halliburton Energy Services, Inc. March 7, 2001 Sensor Measure Point - PCG

Слайд 8

© 2001, Halliburton Energy Services, Inc.

March 7, 2001

Bottom Ring to Probe Bottom Distance

Measure

© 2001, Halliburton Energy Services, Inc. March 7, 2001 Bottom Ring to
the distance from the Bottom Ring Assembly to the bottom of the probe.
(6.3’)

Слайд 9

© 2001, Halliburton Energy Services, Inc.

March 7, 2001

Obtain BHA Tally

Bit 8 ½” 0.75’
Motor 6 ¾” 24.35’
Stabilizer 6

© 2001, Halliburton Energy Services, Inc. March 7, 2001 Obtain BHA Tally
¾” 5.72’
NMDC 6 ¾” 29.87’
HOS 6 ¾” 6.21’
X-over sub 6 ¾” 2.37’
NMCD 6 ¾” 28.53’

Слайд 10

© 2001, Halliburton Energy Services, Inc.

March 7, 2001

Obtain Bore Depth from Spacer

© 2001, Halliburton Energy Services, Inc. March 7, 2001 Obtain Bore Depth
Stack Calculations

54.25”

54.25”

Слайд 11

© 2001, Halliburton Energy Services, Inc.

March 7, 2001

Calculations

Add lengths from bit to

© 2001, Halliburton Energy Services, Inc. March 7, 2001 Calculations Add lengths
top of MWD mounting sub or collar
66.9’
Subtract HOS Bore Depth
62.38’
Subtract distance from bottom ring to bottom of probe
56.08’
Add sensor measure point (PCD)
56.94’