- 2. Operation panel instructions: Actual temperature Setting temperature LED Running state KEY Input key Power switch Lock
- 3. When system powers on and passes self-inspection, it enters operation status and displays setup temperature and
- 4. 200 u 65 It shows percentage of manual output power, 99% at maximum and 0% at
- 5. Function parameter settings Function parameter settings include: Regular function settings—temperature alarm upper limit, temperature alarm lower
- 6. TC-- -J- Short press Short press TC-- -K- C--F -C50 Short press Enter selection zone of
- 7. 20 -KP- Set up by通过 , setup method is the same as that of temperature settings.
- 9. Скачать презентацию
Слайд 2Operation panel instructions:
Actual temperature
Setting temperature
LED
Running state
KEY
Input key
Power switch
Lock position
Handle position
Alarm
Operation panel instructions:
Actual temperature
Setting temperature
LED
Running state
KEY
Input key
Power switch
Lock position
Handle position
Alarm
Thermocouple offline
Thermocouple connected reversely
Heater is disconnected
Silicon controlled breakdown
PV line is designed to be a four-digit nixie tube. In normal condition, it shows temperature of control target and in event of alarm, it shows malfunction code:
SP line is designed to be a four-digit nixie tube. In normal condition, it shows setting temperature:
Three indicators are soft start indicator, automatic operation indicator and manual indicator from left to right.
After initial power on, system enters soft start status. Dehumidify heating ring. Output power and operation time of soft start can be set up by menu. When soft start, this indicator flashes.
When system enter automatic constant temperature operation status, this indicator flashes.
When system enters manual operation status, this indicator flashes
PV
SP
SOFT
AUTO
MANU
E-01: Temp over
E-02: TC open
E-03: TC reverse
E-04: Heater open
E-05: Triac latch
Thermocouple is offline or no thermocouple is connected
Reverse connection of thermoelectricity polarity
E- 03
E- 02
Temperature out of range
E- 01
Setting temperature is 200 ℃
Setting temperature is 200 ℉
c200
F200
Heating ring is disconnected or no heating ring
Silicon controlled breakdown and short circuit
E- 04
E- 05
Thermocouple short circuit
E- 06
SENRITEC
Hot runner systens
Слайд 3When system powers on and passes self-inspection, it enters operation status and
When system powers on and passes self-inspection, it enters operation status and
How to set up temperature
200
c 200
201
c 201
200
c 200
Single press
Single press
Setup temperature increases by one degree with each press
Setup temperature decreases by one degree with each press
200
c 200
200
c 215
200
c 198
Long press
Long press
Setup temperature increases continuously, 5 degree in every second
Setup temperature decreases continuously, 5 degrees in every second
Single press
tens digit of setup temperature starts to flash
200
c 200
210
c 210
200
c 200
Single press
Single press
Setup temperature increases 10 degree by each press
Setup temperature decreases 10 by each press
200
c 200
280
c 280
120
c 120
Long press
Long press
Setup temperature increases continuously, 50 degree in every second
Setup temperature decreases continuously, 50 degrees in every second
Single press
Hundreds digit of setup temperature starts to flash
200
c 200
300
c 300
200
c 200
Single press
Single press
Setup temperature increases 100 degree by each press
Setup temperature decreases 100 degree by each press
200
c 200
450
c 450
000
c 000
Long press
Long press
Setup temperature increases continuously, 500 degree in every second
Setup temperature decreases continuously, 500 degrees in every second
Single press
Setup temperature has no flash digit
After parameter setting, you can press both Next key and Function key to store data quickly, or if there is no other press within 3 seconds, system data will be saved in EEPROM until the next time parameter is modified by user. Maximum setup temperature is 450℃.
200
c 200
Слайд 4200
u 65
It shows percentage of manual output power, 99% at maximum and
200
u 65
It shows percentage of manual output power, 99% at maximum and
It shows current actual status. It may be actual temperature or alarm code.
Operation parameter monitoring
200
c 200
200
u50
200
n04.1
Single press
Single press
The lower line shows current output power percentage
The lower line shows current load current value
Status transition and display
After power on the controller, if initial target temperature is lower than 100 and it is in soft start mode, then system enters soft start mode automatically. If system is in soft start mode after starting up, flashes in every second. Soft start time and output power can be set up in the menu.
When soft start is over, it enters automatic operation mode and flashes in every second. After system power on, if it is detected that target value is higher than 100 degree or soft start mode is off, then it enters automatic operation mode.
In automatic operation status, long press to enter manual state.
In manual status, long press to return to automatic operation state.
In manual operation status, flashes in every second.
In manual operation status, SV screen shows manual output power, SP shows current state. Method of manual output power is the same as temperature setup .
200
u 65
It shows percentage of manual output power, 99% at maximum and 0% at minimum.
It shows current actual status. It may be actual temperature or alarm code.
* * * * *
* * * * *
Слайд 5Function parameter settings
Function parameter settings include:
Regular function settings—temperature alarm
Function parameter settings
Function parameter settings include:
Regular function settings—temperature alarm
Advanced function settings-----thermocouple type, selection of centigrade and Fahrenheit, PID parameter, etc.
200
c 200
20
T-oU
-20
T-Lo
Long press
Enter temperature upper limit settings
Short press
Enter temperature lower limit settings
Set up by , method is the same as that of temperature settings
Set up by , method is the same as that of temperature settings
Enter advanced menu password settings
Long press
Long press
CodE
nc00
Long press When password settings are correct, long press this key will enter advanced settings menu.
Short press
Set up by , method is the same as that of temperature settings
CODE is 0—99, only when correct number is set up can you enter advanced menu.
Enter advanced menu settings zone
BACK
Enter parameter settings menu in automatic state
-on-
LOCK
Short press
Long press
-OFF
LOCK
Short press
Short press
Слайд 6TC--
-J-
Short press
Short press
TC--
-K-
C--F
-C50
Short press
Enter selection zone of centigrade
TC--
-J-
Short press
Short press
TC--
-K-
C--F
-C50
Short press
Enter selection zone of centigrade
C--F
-F60
Short press
Enter control method setup area
Long press
Long press
Setup menu of type J and type K thermocouple
Setup menu of centigrade and Fahrenheit
cont
SSR
cont
PWM
Short press
Enter time settings zone of soft start
Long press
Setup menu of zero crossing control and phase-shifting control mode
SOFT
t. 01
Set up by , setup method is the same as that of temperature settings.
Soft start is mainly for dehumidify heater. When mould is not used for a long time, please select soft start mode. PWM soft start mode is the best. Setup time shall not be less than 60 minutes. If the mould is always in use, set up short time, e.g., 2 minutes.
Short press
Long press
SOFT
P 10
Set up by , setup method is the same as that of temperature settings.
Soft start is mainly for dehumidify heater. When mould is not used for a long time, please select soft start mode. PWM soft start mode is the best. Setup power shall not exceed 10%.
Long press
Enter setup zone of soft start power
Short press
Short press
Short press
Short press
Short press
Слайд 720
-KP-
Set up by通过 , setup method is the same as that of
20
-KP-
Set up by通过 , setup method is the same as that of
KP value is scale-up factor. When AP is ON, temperature controller will calculate and save this value based on heater features automatically. Do not change this number generally. Only in special circumstances will technicians be allowed to change this number.
Long press
60
-Ki-
Short press
Enter parameter I setup zone of PID controller
Set up by setup method is the same as that of temperature settings.
Ki number if integral scale-up factor. When AP is ON, temperature controller will calculate and save this value based on heater features automatically. Do not change this number generally. Only in special circumstances will technicians be allowed to change this number.
15
-Kd-
Short press
Enter D parameter setup zone of PID controller
Set up by , setup method is the same as that of temperature settings. Kd is differential scale-up factor. When AP is ON, temperature controller will calculate and save this value based on heater features automatically. Do not change this number generally. Only in special circumstances will technicians be allowed to change this number.
Long press
Long press
-AP-
_ON
Short press
Enter parameter automatic adjustment switch setup zone
Short press
Short press
-AP-
_OFF
Long press
Short press
Generally, AP is ON.
When AP is ON, controller tests heater functions automatically during each power on and temperature rise. When temperature controller gets accurate heater parameter, it performs accurate control.
When AP is OFF, controller will not test heater function, but withdraw parameter from previous record. If temperature controller controls the same heating ring, it is stable.