Содержание

Слайд 2

Topic 4
Multi-pulse SCR Rectifiers

Topic 4 Multi-pulse SCR Rectifiers

Слайд 3

Lecture Topics
Six-pulse SCR Rectifier (Building Block)
12-, 18- and 24-pulse

Lecture Topics Six-pulse SCR Rectifier (Building Block) 12-, 18- and 24-pulse SCR
SCR Rectifiers
THD and PF

Multi-pulse SCR Rectifiers

Слайд 4

Why Use Multi-pulse SCR Rectifiers?
To reduce line THD
To improve input

Why Use Multi-pulse SCR Rectifiers? To reduce line THD To improve input
power factor
To avoid semiconductor devices in series.

Multi-pulse SCR Rectifiers

Слайд 5

Converter Configuration

Assumption: 1) Ideal SCRs - no power loss
2) dc

Converter Configuration Assumption: 1) Ideal SCRs - no power loss 2) dc
current ripple free
Use constant current source Id as a load

Six-pulse SCR Rectifier

Слайд 6

Waveforms

Average dc voltage

Six-pulse SCR Rectifier

Waveforms Average dc voltage Six-pulse SCR Rectifier

Слайд 7

Fourier Analysis

RMS current

THD

Six-pulse SCR Rectifier

Fourier Analysis RMS current THD Six-pulse SCR Rectifier

Слайд 8

Power Factor (PF)

Displacement Power Factor

Overall Power Factor

Six-pulse SCR Rectifier

Power Factor (PF) Displacement Power Factor Overall Power Factor Six-pulse SCR Rectifier

Слайд 9

Waveforms at Various Firing Angles

Six-pulse SCR Rectifier

Waveforms at Various Firing Angles Six-pulse SCR Rectifier

Слайд 10

Effect of Line Inductance Ls

Six-pulse SCR Rectifier

Effect of Line Inductance Ls Six-pulse SCR Rectifier

Слайд 11

Waveform During SCR Commutation

Six-pulse SCR Rectifier

Waveform During SCR Commutation Six-pulse SCR Rectifier

Слайд 12

DC Voltage Reduction (caused by commutation)

S1 and S5 on (during

DC Voltage Reduction (caused by commutation) S1 and S5 on (during commutation)
commutation)

from which

Since ia + ic = Id, and id is constant

from which

Six-pulse SCR Rectifier

Слайд 13

DC Voltage Reduction

Since

Shaded Area Aγ

Average dc voltage loss

DC Voltage Reduction Since Shaded Area Aγ Average dc voltage loss Average
Average dc output voltage

Six-pulse SCR Rectifier

Слайд 14

Commutation Interval

Aγ can be rearranged as

where

Substitute

from which

Six-pulse SCR

Commutation Interval Aγ can be rearranged as where Substitute from which Six-pulse
Rectifier

into the above equation

Слайд 15

Line Current Waveforms

Ls = 0.05pu

Six-pulse SCR Rectifier

Line Current Waveforms Ls = 0.05pu Six-pulse SCR Rectifier

Слайд 16

Line Current THD

Six-pulse SCR Rectifier

Line Current THD Six-pulse SCR Rectifier

Слайд 17

Power Factor

Six-pulse SCR Rectifier

Power Factor Six-pulse SCR Rectifier

Слайд 18

Topology

Main Benefits
- Low line current THD
- No SCRs

Topology Main Benefits - Low line current THD - No SCRs in series 12-pulse SCR Rectifier
in series

12-pulse SCR Rectifier

Слайд 19

Application Example

Used for current source inverter (CSI) fed drive

12-pulse SCR

Application Example Used for current source inverter (CSI) fed drive 12-pulse SCR Rectifier
Rectifier

Слайд 20

Waveforms of Idealized Rectifier (Ls = Llk = 0)

12-pulse SCR Rectifier

Waveforms of Idealized Rectifier (Ls = Llk = 0) 12-pulse SCR Rectifier

Слайд 21

Fourier Analysis

Secondary currents

12-pulse SCR Rectifier

Fourier Analysis Secondary currents 12-pulse SCR Rectifier

Слайд 22

Fourier Analysis (continued)

Secondary currents referred to the primary side

Primary

Fourier Analysis (continued) Secondary currents referred to the primary side Primary line current 12-pulse SCR Rectifier
line current

12-pulse SCR Rectifier

Слайд 23

Line Current THD

Secondary side

Primary side

12-pulse SCR Rectifier

Line Current THD Secondary side Primary side 12-pulse SCR Rectifier

Слайд 24

Line Current Waveform (Ls ≠ 0 )

12-pulse SCR Rectifier

Line Current Waveform (Ls ≠ 0 ) 12-pulse SCR Rectifier

Слайд 25

THD and PF

12-pulse SCR Rectifier

THD and PF 12-pulse SCR Rectifier

Слайд 26

Rectifier Configuration

18-pulse SCR Rectifier

Rectifier Configuration 18-pulse SCR Rectifier

Слайд 27

Waveforms

18-pulse SCR Rectifier

Waveforms 18-pulse SCR Rectifier

Слайд 28

Line Current THD

18-pulse SCR Rectifier

Line Current THD 18-pulse SCR Rectifier

Слайд 29

Rectifier Configuration

24-pulse SCR Rectifier

Rectifier Configuration 24-pulse SCR Rectifier

Слайд 30

Line Current THD

24-pulse SCR Rectifier

Line Current THD 24-pulse SCR Rectifier
Имя файла: slides-topic.pptx
Количество просмотров: 87
Количество скачиваний: 0