parker pumppu P2 design

Слайд 2

P2 Standard pump

P2

P2 Standard pump P2

Слайд 4

Displacement cc/rev 60 75 105 145
Pressure (bar) (cont./ peak) All sizes 320 / 370
Self priming speed (rpm) 2800 2500 2300 2200
Noise

Displacement cc/rev 60 75 105 145 Pressure (bar) (cont./ peak) All sizes
Level (dB(A) at 1800 rpm and 250 bar < 74 < 76 < 78 < 80
Controls
Load sensing w. pressure cut off Yes Yes Yes Yes
Pressure/ flow / torque Yes Yes Yes Yes
Pressure/ flow / torque / summation Yes Yes Yes Yes
Electronic flow control Planned
ß10 lifetime @ max. flow and pressure 5000 h @ max ratings
Flange Standard SAE C-4 SAE C-2/4 SAE C-2/4 SAE D-4
Optional SAE B-2 SAE C-2
Shafts (all SAE spline) Standard C C C D
Optional B-B C-C D C
Optional B
Through shaft at full torque Yes Yes Yes Yes
Rear ports Yes Yes

P2 Pump Family

Слайд 5

Noise - Air borne

P2/P3 Presentation/ Design

Noise - Air borne P2/P3 Presentation/ Design

Слайд 6

Noise - Hydraulic

P2/P3 Presentation/ Design

Noise - Hydraulic P2/P3 Presentation/ Design

Слайд 7

Parts produced in house

P2/P3 – Production in Europe

Parts produced in house P2/P3 – Production in Europe

Слайд 8

Parts from sub contractors

P2/P3 – Production in Europe

Parts from sub contractors P2/P3 – Production in Europe

Слайд 9

P2 - LA (Load Sensing with Maximum Pressure Control)

P2/P3 Presentation/ Controls

A

B

P2 - LA (Load Sensing with Maximum Pressure Control) P2/P3 Presentation/ Controls A B

Слайд 10

P2 - LA (Load Sensing with Maximum Pressure Control)

P2/P3 Presentation/ Controls

P2 - LA (Load Sensing with Maximum Pressure Control) P2/P3 Presentation/ Controls

Слайд 11

P2 - LA (Load Sensing with Maximum Pressure Control)

(X) LS signal

Drain to

P2 - LA (Load Sensing with Maximum Pressure Control) (X) LS signal
case

Pump pressure to the servo piston
(Onstroke the pump)

Control pressure to the servo piston
(Destroke the pump)

Δ - p adjusting screw

Max. pressure adjusting screw

P2/P3 Presentation/ Controls

Слайд 12

Location of orifices
P2/P3 - 075, -105, - 145

Bleed-Off Orifice
M6 x 6

Location of orifices P2/P3 - 075, -105, - 145 Bleed-Off Orifice M6
x 0,4(diameter in mm)

P2/P3 Presentation/ Design

Orifice only when there is a torque or torque summation control (1/16 x 0,8 pipe orifice)

10 mm spools

Слайд 13

P2 TA ( 20%-60%)
P2 TC ( 50%-90%)
Torque
Load Sensing and
Maximum Pressure Control

P2

P2 TA ( 20%-60%) P2 TC ( 50%-90%) Torque Load Sensing and
TA, TC controls

Слайд 14

Pressure, internal feed, to the torque control.

Drain to case.

P2 TA, TC controls

Torque

Pressure, internal feed, to the torque control. Drain to case. P2 TA,
Control Cartridge

Слайд 15

P2 TA, TC, controls

Torque Control Cartridge

P2 TA, TC, controls Torque Control Cartridge
Имя файла: parker-pumppu-P2-design.pptx
Количество просмотров: 113
Количество скачиваний: 0